Equipment landscape

North American setup worksheet · 120 V / 60 Hz

Build the A3 Apex Pro ecosystem on paper first.

Start with the official included bundle, map multiple Energy Bar 832 units, add a bounded set of probes and expansion modules, and document alerts a person will verify.

Session onlySource backedNo live control

Looking for “Apex v3 Pro”? The current official product name is Neptune Systems A3 Apex Pro System.

Official included bundle

Begin with what is actually in the box.

This inventory follows Neptune's current A3 Apex Pro product listing. Salinity, additional Energy Bars, and expansion modules are optional—not included.

01

Apex Pro Base Unit

System core

02

Energy Bar 832

AquaBus network

03

6 ft AquaBus cable

AquaBus network

04

Lab-grade double-junction pH probe

Built-in pH probe port

05

Lab-grade double-junction ORP probe

Built-in ORP probe port

06

Temperature probe

Built-in temperature probe port

07

Optical leak sensor

A3 Pro FMM input 1

08

15-inch liquid level sensor

A3 Pro FMM input 2

09

pH calibration solutions

Setup consumable

Catalog revision a3-apex-pro-na-2026.07.17.3 · verified 2026-07-17 · A3 Apex Pro included bundle plus a bounded planning subset of current expansion families.

Session-only planning worksheet

Map the ecosystem before installation.

Your worksheet contents are not saved or sent. Reloading or leaving this page clears them. With analytics consent, Reef Warden measures only content-free component adjustments and worksheet actions.

Planning topology2 hosts · 5 mapped endpoints

Default A3 Apex Pro bundle loaded.

Left connectionsFour built-in FMM inputsBase-unit inputs only
1
FMM input 1Included optical leak sensor
2
FMM input 2Included 15-inch liquid level sensor
3
FMM input 3Available compatible input
4
FMM input 4Available compatible input
Built into the corepH / ORP BNC inputsIncluded-bundle configuration
BNC 1Configured pHIncluded pH probe
BNC 2Configured ORPIncluded ORP probe
System coreA3 Apex ProIncluded pH · ORP · temperature6 digital inputs · 4 variable 0–10 V outputs
Right planning branchTrident via 1LINKNot a dedicated A3 base port
No Trident selectedAdd one under Endpoints and probes to map its 1LINK host.

Visual analyzer grouping only. Every Trident follows the exact 1LINK assignment shown here.

Bottom networkAquaBus-connected hosts
USB-shaped connectors — never USB
Energy + connection hubEnergy Bar 832 10 assigned connections · 0 / 8 AC outlets planned
Energy Bar 832

Plan all eight AC outlets

Session only · no Fusion connection or live control

Choose an Energy Bar, open an outlet, and document its label and Fusion control-type fields. Blank fallback states and setpoints are intentional. Advanced/manual programming, outlet icons, power thresholds, and actual Apex statements remain outside this worksheet.

AC 1
Outlet 1Unconfigured
Open
AC 2
Outlet 2Unconfigured
Open
AC 3
Outlet 3Unconfigured
Open
AC 4
Outlet 4Unconfigured
Open
AC 5
Outlet 5Unconfigured
Open
AC 6
Outlet 6Unconfigured
Open
AC 7
Outlet 7Unconfigured
Open
AC 8
Outlet 8Unconfigured
Open

Planning boundary: a label and selected wizard do not prove device voltage, current, outlet rating, startup load, safe fallback behavior, probe health, switch logic, setpoint safety, or completed Apex programming.

Capacity screen

Ports available by host

Logical connections only · load data incomplete
A3 Apex Pro Base Unitbase
FMM input
2 / 4
pH-or-ORP port
2 / 2
temperature port
1 / 1
digital switch input
0 / 6
0–10 V channel
0 / 4
Energy Bar 832 1energy-bar
120 V AC outlet
0 / 8
1LINK port
0 / 3
DC24 output
0 / 2

Shared 24 V load: No assigned load

Accessible topology

Exact host and port assignments

Diagram duplicated as text
  1. Included pH probeA3 Apex Pro Base Unit → pH-or-ORP port 1
  2. Included ORP probeA3 Apex Pro Base Unit → pH-or-ORP port 2
  3. Included temperature probeA3 Apex Pro Base Unit → temperature port 1
  4. Included optical leak sensorA3 Apex Pro Base Unit → FMM input 1
  5. Included 15-inch liquid level sensorA3 Apex Pro Base Unit → FMM input 2

Alert + human-response worksheet

Document what a person should verify.

This is not a script builder. It generates no Apex syntax, setpoints, automatic action, or live alarm. Apex Fusion Tasks and programming remain inside Neptune's environment.

Response worksheet 1

Notification note: Neptune ended SMS notifications on November 5, 2025. This worksheet lists current push, email, audible, and human-checklist paths—not SMS.

Commissioning sequence

What the setup actually entails.

Use this as a preparation checklist, then follow the current instructions supplied with every exact device. Installation and programming must be commissioned and failure-tested in the Apex environment.

  1. 01

    Confirm package and electrical market

    Inventory the exact included bundle and confirm this North American worksheet matches the product label and 120 V / 60 Hz service. Do not substitute an international Energy Bar.

  2. 02

    Plan dry, serviceable mounting

    Keep the base, Energy Bars, power supplies, connectors, drip loops, ventilation, and service paths within current manufacturer and qualified electrical guidance. A planner cannot verify branch-circuit or GFCI protection.

  3. 03

    Build and label the AquaBus network

    Record AquaBus and 1LINK routes separately. AquaBus uses USB-shaped connectors but is not USB; never connect it to a computer or other USB device. Neptune limits a 1LINK run to 20 feet from source to device and says not to daisy-chain 1LINK devices.

  4. 04

    Connect network and Apex Fusion

    Follow Neptune's current setup portal for Wi-Fi or Ethernet onboarding, account access, firmware, and device discovery. Reef Warden does not perform this connection.

  5. 05

    Install, calibrate, and commission probes

    Follow the instructions supplied with each exact probe. Record calibration and maintenance dates; do not adopt example thresholds as aquarium-safe setpoints.

  6. 06

    Assign FMM sensor types deliberately

    Confirm every FMM input's sensor type and behavior. LLS response can lag, so do not use it for immediate control such as ATO control.

  7. 07

    Label outlets and verify fallback behavior

    Commission one output at a time, verify the real connected load, and test restart, disconnected-controller, manual-override, and failure behavior under the current Apex documentation.

  8. 08

    Create and test notifications in Apex

    Use Apex Fusion Tasks or Apex programming only in Neptune's environment. Test push, email, and audible alarms with a human present; Reef Warden does not generate or deploy Apex code.

Ports available is not system safe.

This planner does not verify household branch capacity, per-outlet ratings, device voltage/frequency, wet-location installation, cable length or topology, shared 24 V loading, fail-safe behavior, firmware compatibility, or safe aquarium setpoints. Adding another Energy Bar does not create redundancy when both depend on the same circuit or controller.

Primary documentation

Check the current manufacturer record.

Every product fact in this first planner revision is bounded to these Neptune Systems sources. Product names and capabilities can change after the verification date. Neptune Systems, Apex, Apex Fusion, Energy Bar, AquaBus, and 1LINK are third-party names and marks; Reef Warden is not affiliated with or endorsed by Neptune Systems.

Need a different controller ecosystem mapped?

Share the exact model, firmware, electrical market, modules, and visibility goals. Support is documented by model, connection method, and function.